Laffinite II HPLC HbA1c analyzer, original product photograph

Laffinite II

HPLC HbA1c Analyzer

In HPLC, a high-pressure pump drives a liquid mobile phase carrying the sample through a column containing a stationary phase. Differences in how sample components interact with the column allow separation and qualitative or quantitative analysis. The manufacturer describes efficient separation, rapid analysis, sensitivity and reproducibility, with applications across chemistry, biochemistry, medicine, food and environmental analysis.

Product description

Laffinite II measures HbA1c using ion-exchange high-performance liquid chromatography. It samples whole blood from the primary tube, dilutes it with hemolysing buffer, then passes it through a pre-filter and into the ion-exchange column for automatic HbA1c separation.

Product advantages

Select a panel to view its original size. Chromatograms and report values are illustrative manufacturer examples.

Panel 1: sample handling, loader positions, reagents, touchscreen and test modes
Panel 1: sample handling, loader positions, reagents, touchscreen and test modes — View original size
Panel 2: maintenance, STAT testing, reliability and manufacturer example chromatograms
Panel 2: maintenance, STAT testing, reliability and manufacturer example chromatograms — View original size

Features in detail

Sample handling

  • Accepts fingertip blood samples.
  • Mixes samples automatically.
  • Pierces primary sample tube caps.
  • Automatic loader with 15 sample positions, one STAT position, CAL1 (QC1) and CAL2 (QC2).

Operation

  • The column can be stored at room temperature.
  • Patient and specimen information is scanned by barcode automatically.
  • Reagents (Eluent A, Eluent B, Eluent C and Hemolysin L) are housed inside the analyzer and tracked by RFID.
  • A 10.4-inch HD touchscreen provides an intuitive interface.

Test modes

  • The three modes use the same reagents.

Maintenance

  • Daily maintenance runs automatically.
  • The system supports original calibration and quality-control products.

STAT testing

  • A dedicated STAT sample position supports urgent samples.

Result reliability

  • The manufacturer states no clinical interference from labile A1c or HbC, HbD, HbE and HbS variants.
  • Reported precision is CV ≤1.5%.

Chromatographic reporting

  • Common hemoglobin variants are shown in dedicated windows.
  • The feature panel shows HbC, HbS and HbD/E examples with HbA1c results.
  • The reporting examples include β-thalassemia results with HbA2 and HbF.
  • A quick test mode is illustrated.

Test modes and analysis time

Test modeAnalysis time per test
A1c-R118 seconds
A1c150 seconds
A2/F300 seconds

Manufacturer report examples

The following values are illustrative results from the manufacturer panels, not device specifications or reference ranges.

  • HbC example — HbC: 42.6%; HbA1c: 5.3%
  • HbS example — HbS: 38.1%; HbA1c: 9.6%
  • HbD/E example — HbD/E: 28.2%; HbA1c: 5.7%
  • HbA2/F example — HbA2: 2.9%; HbF: 1.0%; HbA1c: 4.7%
  • Quick test example — HbA1c: 5.4%
  • Manufacturer comparison illustration: y = 1.002x + 0.066; R² = 0.9985.